Nusantara Data Center.


Nusantara Data Center (NDC) is an Indonesia's largest and most respected Data Center Network trusted by government, ministries, state-owned enterprises, foreign and domestic large companies, telecommunication operators and ISPs in Indonesia.

NDC is a Neutral Data Center that open to International and Local Multi Carrier-Operators. NDCs are integrated into 5 Data Centers in Jakarta, Surabaya, Medan, Pelembang and Batam, within the Mora Internet eXchange Point (Mora IXP) network, and connected to Public Data Center and other Exchange-Point in Indonesia (Open-IXP, APJII, Technovillage, Cyber-Building, Cyber-CSF, IDC-D3, etc).

Designed with modern data center concept, we prioritize the security, reliability, efficiency and availability of services and give International and SLA standards guarantee. NDC is also supported by multi-backbone network and multi-redundancy fiber optic which connected to international and domestic POP that has been widely trusted by international operators such as Google, Facebook, Akamai, Netflix, etc.

NDC STANDARD AND SLA

  • Tier III : Jakarta, Batam
  • Tier II : Surabaya, Medan, Palembang
  • SLA : 99,98%
  • ISO : 270001, 9001

NDC SERVICES

  • Collocation Service
  • Disaster Recovery Center
  • Virtual Private Server
  • Public Cloud Service
  • Private Cloud Service
  • ExpressConnectTM to Equinix Cloud Exchange
  • DR as a Service
  • Backup as a Service
  • Migration Service

Designed with high quality building, Nusantara Data Center is TIA 942 based recommendation:

Site space and layout

Proper space allocation for a data centre starts with ensuring that space can be easily reallocated to changing environments and growth

Cabling infrastructure

Standard specifies a generic, permanent telecommunications cabling system and provides specifications for the following recognized cabling media

Tiered reliability

Standard includes an informative annex with data centre availability tiers.

Environmental considerations

A standard to the equipment room requirements includes, but are not limited to, fire suppression, humidity levels, operating temperatures, architectural, electrical (power) and mechanical system specifications.

Specification:

  • Perforated floor panel (60 cm height)*/ (40 cm height)**
  • Separated power cord and data cable lines (concealed)
  • under floor panel
  • Loading dock
  • Heat and smoke sensors
  • Fire Suppression System FM-200
  • CCTV Cameras
  • Network Operation Center 24/7

Power Management

  • Main Power PLN 1280 KVA*/ 240 KVA**
  • PDU (Power Distribution Unit)
  • UPS 3 x 250 KVA*/ UPS 2 x 125 KVA**
  • Genset 80 KVA + AMF/ATS**
  • Genset 2 x 1875 KVA*

Access Door

  • Building main entrance with key card
  • Access Door: 2-door entrance to computer room with key card and key code.
  • CCTV in entrance and computer room.
  • Rack and key.

Air Conditioner

  • Type: DX Air Cooled, Down Flow, CITEC*/ Small ICOM**
  • Cooling capacity: 19.5 kW at 22 ° C dB, 50% RH
  • Sensible capacity: 18.8 kW at 22 ° C dB, 50% RH
  • AC Precision 4 x 107 KVA
  • Refrigerant: R407C
  • Indoor dimensions: 850 x 875 x 1970 mm


  • Complements:
  • Single-circuit system
  • Infrared humidifier
  • Electric heater
  • Dehumidifier
  • Event log (up to 400 events)
  • Water leak detection
  • Air flow loss alarm

Detection Devices

  • FenwalNet 6000 with battery Intelligent Control Panel.
  • Addressable Ionization Smoke Detector.
  • Addressable Photoelectric Smoke Detector.
  • AI Monitor Module (ACID).
  • Double Action Manual Pull Station.
  • Suppression Abort Station.
  • Multitone with strobe.
  • Fire alarm bell.
  • EVACUATION AREA sign lamp.